Rhinoviruses (VP1) antibody and antigen (Recombinant protein)

Diagnostic Rhinoviruses (RV) antibodies (anti-Rhinoviruses, anti-VP1) and antigens (recombinant Rhinoviruses (RV) protein) for Infectious disease VP1 detection in ELISA, colloidal gold-based Lateral flow immunoassay (LFIA), CLIA, TINIA and POCT.

Target products collectionGo to Neurodegenerative diseases diagnostics products collection >>


Product information

Catalog No. Description US $ Price (per mg)
GMP-IVD-P039-Tg001-Ag01 Recombinant human Rhinoviruses (RV) VP1 Protein 3090
GMP-IVD-P039-Tg001-Ab01 Anti-human Rhinoviruses (RV) VP1 mouse monoclonal antibody (mAb) 1953
GMP-IVD-P039-Tg001-Ab02 Anti-human Rhinoviruses (RV) VP1 mouse monoclonal antibody (mAb) 1953
GMP-IVD-P039-Tg001-Ab03 Anti-human Rhinoviruses (RV) VP1 human monoclonal antibody (mAb) 1953
GMP-IVD-P039-Tg001-Ab04 Anti-human Rhinoviruses (RV) VP1 human monoclonal antibody (mAb) 1953

Size: 1mg | 10mg | 100mg



Product Description

Cat No. of Products GMP-IVD-P039-Tg001-Ag01
Product Name Recombinant human Rhinoviruses (RV) VP1 Protein
Pathogen Rhinoviruses
Target/Biomarker Rhinoviruses(VP1)
Expression platform E.coli
Isotypes Recombinant Antigen
Bioactivity validation Rhinoviruses (VP1) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in VP1 level test of Infectious disease (common cold) and related syndrome evaluation.
Tag His
Products description Recombinant human Rhinoviruses (RV) VP1 Protein was expressed in E.coli - based prokaryotic cell expression system and is expressed with 6 HIS tag at the C-terminus.
Purity Purity: ≥95% (SDS-PAGE)
Application Standard substance, positive control, ELISA test,Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA),immunonephelometry and POCT.
Formulation Supplied as a 0.2 μM filtered solution of PBS,PH7.4.
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.

Cat No. of Products GMP-IVD-P039-Tg001-Ab01, GMP-IVD-P039-Tg001-Ab02
Product Name Anti-human Rhinoviruses (RV) VP1 mouse monoclonal antibody (mAb)
Pathogen Rhinoviruses
Target/Biomarker Rhinoviruses(VP1)
Expression platform CHO
Isotypes Mouse IgG
Bioactivity validation Human Rhinoviruses (VP1) antigen binding, ELISA validated as capture antibody and detection antibody. Pair recommendation with other Rhinoviruses (VP1) antibodies in VP1 level test of Infectious disease (common cold) and related syndrome evaluation.
Tag mFc
Products description Anti-human Rhinoviruses (RV) VP1 mouse monoclonal antibody (mAb) is a monoclonal antibody produced by CHO. The antibody is ELISA validated as capture antibody and detection antibody pair.
Purity Purity: ≥95% (SDS-PAGE)
Application ELISA test, Lateral flow immunoassay (LFIA), colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA), turbidimetric inhibition immuno assay (TINIA), immunonephelometry and POCT.
Formulation Supplied as a 0.2 μM filtered solution of PBS,PH7.4.
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.

Cat No. of Products GMP-IVD-P039-Tg001-Ab03, GMP-IVD-P039-Tg001-Ab04
Product Name Anti-human Rhinoviruses (RV) VP1 human monoclonal antibody (mAb)
Pathogen Rhinoviruses
Target/Biomarker Rhinoviruses(VP1)
Expression platform CHO
Isotypes Human IgG1
Bioactivity validation Human Rhinoviruses (VP1) antigen binding, ELISA validated as capture antibody and detection antibody. Pair recommendation with other Rhinoviruses (VP1) antibodies in VP1 level test of Infectious disease (common cold) and related syndrome evaluation.
Tag hFc
Products description Anti-human Rhinoviruses (RV) VP1 human monoclonal antibody (mAb) is a monoclonal antibody produced by CHO. The antibody is ELISA validated as capture antibody and detection antibody pair.
Purity Purity: ≥95% (SDS-PAGE)
Application ELISA test, Lateral flow immunoassay (LFIA), colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA), turbidimetric inhibition immuno assay (TINIA), immunonephelometry and POCT.
Formulation Supplied as a 0.2 μM filtered solution of PBS,PH7.4.
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.

Reference




    Validation Data


    Click to get more Data / Case study about the product.



    Target/Biomarker information

    Rhinoviruses (RVs) are the main cause of the common cold worldwide. To date, more than 160 types of the virus have been recognized, categorized into three major species - A, B, and C. There are currently no approved vaccines available to prevent infection with RVs



    About GDU


    GDU

    GDU helps global diagnostic partners in high quality of raw material discovery, development, and application. GDU believes in Protein&antibody Innovation for more reliable diagnostic solutions.

    Comments


    Linda Wilson 2024-01-16 02:05:18
    This antigen is highly stable and provides good data quality for Lateral Flow Immunoassay (LFIA) applications. This increases diagnostic accuracy because of its high performance.

    Leave a comment