Forchlorfenuron antibody/antigen (BSA/OVA/KLH conjugated hapten)

anti-Forchlorfenuron antibody and Carrier-coupled antigen/immunogen (hapten-carrier conjugates)

Target products collectionGo to Hormones diagnostics products collection >>


Product information

Catalog No.DescriptionUS $ Price (per mg)
GMP-SMT-192-11. BSA-Forchlorfenuron
2. Anti-Forchlorfenuron mouse monoclonal antibody
$2709.00
GMP-SMT-192-21. OVA-Forchlorfenuron
2. Anti-Forchlorfenuron mouse monoclonal antibody
$2709.00
GMP-SMT-192-31. BSA-Forchlorfenuron
2. Anti-Forchlorfenuron human monoclonal antibody
$2709.00
GMP-SMT-192-41. OVA-Forchlorfenuron
2. Anti-Forchlorfenuron human monoclonal antibody
$2709.00
GMP-SMT-192-Ag-1BSA-Forchlorfenuron$756.00
GMP-SMT-192-Ag-2OVA-Forchlorfenuron$756.00
GMP-SMT-192-Ab-1Anti-Forchlorfenuron mouse monoclonal antibody$1953.00
GMP-SMT-192-Ab-2Anti-Forchlorfenuron human monoclonal antibody$1953.00

Size: 1mg | 10mg | 100mg



Product Description


BSA-Forchlorfenuron

Cat No.GMP-SMT-192-Ag-1
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products descriptionCompetitive immunoassay-validated hapten-carrier conjugates BSA-Forchlorfenuron with anti-Hapten antibody. The hapten hapten-carrier conjugates BSA-Forchlorfenuron had been validated with our anti-Hapten antibody Anti-Forchlorfenuron mouse monoclonal antibody via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


OVA-Forchlorfenuron

Cat No.GMP-SMT-192-Ag-2
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products descriptionCompetitive immunoassay-validated hapten-carrier conjugates OVA-Forchlorfenuron with anti-Hapten antibody. The hapten hapten-carrier conjugates OVA-Forchlorfenuron had been validated with our anti-Hapten antibody Anti-Forchlorfenuron mouse monoclonal antibody via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Forchlorfenuron mouse monoclonal antibody

Cat No.GMP-SMT-192-Ab-1
Host of AntibodyMouse IgG
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb)0.20
Products descriptionThe anti-Hapten antibody against hapten Forchlorfenuron had been validated with our hapten hapten-carrier conjugates BSA-Forchlorfenuron via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Forchlorfenuron human monoclonal antibody

Cat No.GMP-SMT-192-Ab-2
Host of AntibodyHuman IgG1
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb)0.20
Products descriptionThe anti-Hapten antibody against hapten Forchlorfenuron had been validated with our hapten hapten-carrier conjugates BSA-Forchlorfenuron via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Reference




    Validation Data


    Click to get more Data / Case study about the product.



    Biomarker Information


    1. What is Forchlorfenuron, and what is its role in in vitro diagnosis?

    Forchlorfenuron, chemically known as CPPU (N-(2-chloro-4-pyridyl)-N'-phenylurea), represents a pivotal small molecule within the realm of in vitro diagnosis. This chemical compound plays a fundamental role in immunoassays, a cornerstone of diagnostic techniques employed for detecting and quantifying specific target molecules in biological samples.

    (Serial Number 1) Within the context of in vitro diagnosis, Forchlorfenuron assumes a crucial position in immunoassay protocols. Immunoassays, grounded in the principle of specific interactions between antibodies and antigens, are paramount in the field of diagnostics. Forchlorfenuron, in particular, emerges as a critical element functioning as either a competitive antigen or a hapten-carrier conjugate in immunoassays. These immunoassays are meticulously designed to identify and measure specific antibodies or target analytes closely associated with diverse diseases or medical conditions.

    The core function of Forchlorfenuron in in vitro diagnosis revolves around its ability to closely mimic the structural attributes of the target molecule. In doing so, it competes effectively with the actual analyte for binding to specific antibodies. This competitive binding mechanism constitutes the foundational premise of a multitude of immunoassay formats. These formats encompass a spectrum of techniques, including but not limited to enzyme-linked immunosorbent assays (ELISA), radioimmunoassays (RIA), and chemiluminescent immunoassays (CLIA).

    By leveraging Forchlorfenuron as a competitive antigen, healthcare professionals, researchers, and diagnosticians gain the capacity to accurately and precisely determine the concentration of antibodies or target molecules within clinical samples. This capability proves to be instrumental in the diagnosis, monitoring, and management of a wide array of diseases and medical conditions.

    2. Why measure Forchlorfenuron?

    (Serial Number 2) The measurement of Forchlorfenuron holds profound significance within in vitro diagnosis, underpinned by several compelling reasons, particularly within the diagnostic landscape:

    a. Disease Detection: Immunoassays, prominently featuring Forchlorfenuron, facilitate the precise detection of specific antibodies or analytes closely linked to an extensive spectrum of diseases and medical conditions. This capability proves indispensable for the early diagnosis of diseases, enabling timely and effective medical interventions.

    b. Clinical Decision-Making: Accurate measurement of Forchlorfenuron within patient samples empowers healthcare professionals to make informed and evidence-based decisions concerning treatment strategies and patient management. It furnishes critical insights into disease progression, response to therapeutic interventions, and the formulation of tailored treatment plans.

    c. Research Advancements: Forchlorfenuron serves as an invaluable tool within the research landscape, particularly in the development of diagnostic tests and assays. Its application as a standard in assay development allows for meticulous validation and optimization of diagnostic methods. This not only bolsters diagnostic accuracy but also fuels ongoing advancements in diagnostic research.

    d. Public Health Surveillance: Within the domain of public health, the measurement of Forchlorfenuron assumes a pivotal role in the monitoring and surveillance of infectious diseases. It provides the essential framework for timely interventions and the implementation of preventive measures to mitigate disease outbreaks and safeguard public health.

    e. Quality Assurance: In industries with a stake in diagnostics, including pharmaceuticals and biotechnology, Forchlorfenuron-based immunoassays play an indispensable role in quality control. These assays are employed to ascertain the accuracy and reliability of diagnostic reagents and tests, thus upholding industry standards and ensuring the efficacy of diagnostic products.

    In summary, the measurement of Forchlorfenuron stands as a linchpin within the realm of in vitro diagnosis, offering a powerful means to accurately detect and quantify specific antibodies and target analytes associated with an expansive spectrum of diseases and medical conditions. Biopharmaceutical companies specializing in anti-Forchlorfenuron antibodies and Forchlorfenuron-based competitive antigens emerge as pivotal contributors to the advancement of diagnostic capabilities. Their efforts not only facilitate enhanced healthcare delivery but also underscore their commitment to driving innovation and excellence within the diagnostic landscape, ultimately benefiting patients, healthcare providers, and the broader healthcare ecosystem.



    About GDU


    GDU

    GDU helps global diagnostic partners in high quality of raw material discovery, development, and application. GDU believes in Protein&antibody Innovation for more reliable diagnostic solutions.