Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antibody and antigen (Recombinant protein)
Diagnostic Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antibodies (anti-Matrix Metalloproteinase Inhibitor-1, anti-TIMP-1) and antigens (recombinant Matrix Metalloproteinase Inhibitor-1 (TIMP-1) protein) for Cardiovascular disease TIMP-1 detection in ELISA, colloidal gold-based Lateral flow immunoassay (LFIA), CLIA, TINIA and POCT.
Go to Cardiovascular disease diagnostics products collection >>
Product information
Catalog No. | Description | US $ Price (per mg) |
---|---|---|
GMP-h-TIMP-1-Ag01 | Recombinant human TIMP-1 Protein | $3090.00 |
GMP-h-TIMP-1-Ab01 | Anti-human TIMP-1 mouse monoclonal antibody (mAb) | $1953.00 |
GMP-h-TIMP-1-Ab02 | Anti-human TIMP-1 mouse monoclonal antibody (mAb) | $1953.00 |
GMP-h-TIMP-1-Ab03 | Anti-human TIMP-1 human monoclonal antibody (mAb) | $1953.00 |
GMP-h-TIMP-1-Ab04 | Anti-human TIMP-1 human monoclonal antibody (mAb) | $1953.00 |
Size: 1mg | 10mg | 100mg
Product Description
Cat No. of Pruducts | GMP-h-TIMP-1-Ag01 |
Product Name | Recombinant human TIMP-1 Protein |
Target/Biomarker | Matrix Metalloproteinase Inhibitor-1 (TIMP-1) |
Alias of Target/Biomarker | CLGI, EPA, EPO, HCI, TIMP, TIMP-1 |
Expression platform | mammalian |
Isotypes | Recombinant Antigen |
Bioactivity validation | Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in TIMP-1 level test of Cardiovascular disease (coronary artery stenosis, coronary artery lesions) and related syndrome evaluation |
Products description | Recombinant Human protein was expressed in mammalian cell expression system and is expressed with 6 HIS tag at the C-terminus. |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | positive control, ELISA test,Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation | Supplied as a 0.2 μM filtered solution of PBS,PH7.4. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Cat No. of Pruducts | GMP-h-TIMP-1-Ab01,GMP-h-TIMP-1-Ab02 |
Product Name | Anti-human TIMP-1 mouse monoclonal antibody (mAb) |
Target/Biomarker | Matrix Metalloproteinase Inhibitor-1 (TIMP-1) |
Alias of Target/Biomarker | CLGI, EPA, EPO, HCI, TIMP, TIMP-1 |
Expression platform | CHO |
Isotypes | Mouse IgG |
Bioactivity validation | Human Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antigen binding, ELISA validated as capture antibody and detection antibody. Pair recommendation with other Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antibodies in TIMP-1 level test of Cardiovascular disease (coronary artery stenosis, coronary artery lesions) and related syndrome evaluation. |
Tag | mFc |
Products description | Anti-human TIMP-1 mouse monoclonal antibody (mAb) is a mouse monoclonal antibody produced by CHO technology. The antibody is ELISA validated as capture antibody and detection antibody. Pair recommendation with other Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antibodies. |
Reconized/Reactive Species | Human |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | ELISA test,Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA),immunonephelometry and POCT. |
Formulation | Supplied as a 0.2 μM filtered solution of PBS,PH7.4. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Cat No. of Pruducts | GMP-h-TIMP-1-Ab03,GMP-h-TIMP-1-Ab04 |
Product Name | Anti-human TIMP-1 human monoclonal antibody (mAb) |
Target/Biomarker | Matrix Metalloproteinase Inhibitor-1 (TIMP-1) |
Alias of Target/Biomarker | CLGI, EPA, EPO, HCI, TIMP, TIMP-1 |
Expression platform | CHO |
Isotypes | Human lgG1 |
Bioactivity validation | Human Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antigen binding, ELISA validated as capture antibody and detection antibody. Pair recommendation with other Matrix Metalloproteinase Inhibitor-1 (TIMP-1) antibodies in TIMP-1 level test of Cardiovascular disease (coronary artery stenosis, coronary artery lesions) and related syndrome evaluation. |
Tag | hFc |
Products description | Anti-human TIMP-1 mouse monoclonal antibody (mAb) is a human monoclonal antibody produced by CHO. The antibody is ELISA validated as capture antibody and detection antibody pair. |
Reconized/Reactive Species | Human |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | ELISA test,Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA),immunonephelometry and POCT. |
Formulation | Supplied as a 0.2 μM filtered solution of PBS,PH7.4. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Reference
Validation Data
Click to get more Data / Case study about the product.
Target/Biomarker information
MMP activity is tightly controlled by the endogenous tissue inhibitors of metalloproteinases (TIMPs) comprising 4 homologous members (TIMP-1, TIMP-2, TIMP-3 and TIMP-4). The dynamic balance between MMPs and TIMPs controls extracellular matrix turnover and maintains tissue homeostasis. Alterations in the balance between MMPs and TIMPs are implicated in the pathogenesis of cardiovascular disease。MMP-9/TIMP-1 ratio could be used as biomarkers to predict future cardiovascular events in Chinese patients with mild to moderate coronary artery stenosis. TIMP-1 may also serve as a promising biomarker to predict the outcomes of patients with mild to moderate coronary artery lesions.
About GDU
GDU helps global diagnostic partners in high quality of raw material discovery, development, and application. GDU believes in Protein&antibody Innovation for more reliable diagnostic solutions.
Comments
No comments yet.