PurProX® AAVPure AAV Affinity Chromatography Column

PurProX® AAVPure prepacked AAV affinity chromatography columns are ready-to-use AAV purification columns for FPLC and ÄKTA workflows. Available in 1 mL and 5 mL formats with AAVPure U-1 or U-2 affinity media, they support small-scale AAV affinity purification, chromatography condition screening, and process development without manual column packing.

PurProX® AAVPure U-1 has been tested for binding AAV2, AAV5, AAV6, AAV8, AAV7m8, and AAV-DJ, while U-2 has been tested for binding AAV9. The same AAVPure affinity media is available as bulk resin to support method transfer from early process development toward scale-up.

PurProX® AAV Purification Solution

PurProX® AAVPure Pre-packed AAV Affinity Column Order Information

Product TypeCatalog No.Product NameSizePrice (USD)
Pre-packed ColumnGMV-PurProX-AAVPure-U-1-P1mlPurProX® AAVPure Pre-packed Column-11 mL
Pre-packed ColumnGMV-PurProX-AAVPure-U-2-P1mlPurProX® AAVPure Pre-packed Column-21 mL
Pre-packed ColumnGMV-PurProX-AAVPure-U-1-P5mlPurProX® AAVPure Pre-packed Column-15 mL
Pre-packed ColumnGMV-PurProX-AAVPure-U-2-P5mlPurProX® AAVPure Pre-packed Column-25 mL

PurProX® AAVPure Related AAV Purification Products

Product TypeCatalog No.Product NameSizePrice (USD)
AAV Affinity ResinGMV-PurProX-AAVPure-U-1-10mlPurProX® AAVPure Affinity Resin-110 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-1-25mlPurProX® AAVPure Affinity Resin-125 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-1-50mlPurProX® AAVPure Affinity Resin-150 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-1-250mlPurProX® AAVPure Affinity Resin-1250 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-1-1LPurProX® AAVPure Affinity Resin-11 L
AAV Affinity ResinGMV-PurProX-AAVPure-U-1-5LPurProX® AAVPure Affinity Resin-15 L
AAV Affinity ResinGMV-PurProX-AAVPure-U-2-10mlPurProX® AAVPure Affinity Resin-210 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-2-25mlPurProX® AAVPure Affinity Resin-225 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-2-50mlPurProX® AAVPure Affinity Resin-250 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-2-250mlPurProX® AAVPure Affinity Resin-2250 mL
AAV Affinity ResinGMV-PurProX-AAVPure-U-2-1LPurProX® AAVPure Affinity Resin-21 L
AAV Affinity ResinGMV-PurProX-AAVPure-U-2-5LPurProX® AAVPure Affinity Resin-25 L

PurProX® AAVPure AAV Affinity Chromatography Column Specifications

Catalog numberGMV-PurProX-AAVPure-U-1-P; GMV-PurProX-AAVPure-U-2-P
Product namePurProX® AAVPure Pre-packed Column
Support matrixPolymer resin
Immobilized ligandVHH
Serotype affinityGMV-PurProX-AAVPure-U-1-P: Tested-Binding- AAV2, AAV5, AAV6, AAV8, AAV7m8, AAV-DJ;
GMV-PurProX-AAVPure-U-2-P: Tested-Binding- AAV9
Binding capacity~3E+14 vp per mL resin
Shipping solvent2% Benzyl Alcohol
Average particle size50 µm
Recommended flow rate≥3-minute residence time
Mechanical resistance10 bar (1 MPa)
pH range2–10
Operating temperatureRT
Storage instructionDo not freeze

PurProX® AAVPure AAV Affinity Column Performance and Validation

Fig 1. AAV8 purified with AAV affinity resin by ÄKTA. Chromatogram illustrating the purification of AAV8 on the ÄKTA system. The x-axis represents time; the y-axis shows absorbance (A280 for protein, A260 for nucleic acid) and conductivity. Peaks indicate sample loading, washing, and elution phases.

AAV8 purification chromatogram on ÄKTA

Fig 2. Silver staining of AAV8 purification. Silver-stained SDS-PAGE gel showing protein bands from AAV8 purification fractions. Lanes include molecular weight markers, lysate, flow-through (FT), and elution fractions. Capsid proteins (VP1, VP2, VP3) are visible in the elution lane at ~60–80 kDa.

Silver-stained SDS-PAGE of AAV8 purification

Fig 3. Silver staining of AAV6 purification. Silver-stained SDS-PAGE gel depicting protein bands from AAV6 purification fractions. Lanes show markers, lysate, flow-through (FT), and elution, with AAV6 capsid proteins (VP1, VP2, VP3) prominent in the elution lane.

Silver-stained SDS-PAGE of AAV6 purification

PurProX® AAVPure Recovery Across AAV2, AAV5, AAV6 and AAV8

SerotypeInitial AAV (vg)Purified AAV (vg)Recovery Rate (%)
AAV25.72E+125.19E+1290.73
AAV53.36E+133.13E+1393.15
AAV68.28E+127.73E+1293.36
AAV81.33E+131.25E+1393.98
AAV91.45E+131.37E+1394.48

PurProX® AAVPure AAV Affinity Chromatography Column FAQ

What is a prepacked AAV affinity column used for?

The PurProX® AAVPure Pre-packed Column is a ready-to-use chromatography column filled with high-performance AAV purification resin (AAVPure U-1 or U-2). It is designed for small-scale AAV vector purification and process parameter screening without manual column packing.

Which serotypes do the U-1 and U-2 AAV purification columns target?

U-1 is a broad-spectrum variant effective for AAV2, AAV5, AAV6, AAV8, AAV-DJ, and AAV-7m8. U-2 is optimized for AAV9 and its variants, including the AAV-PHP series.

Does the prepacked AAV purification column use the same affinity media as bulk AAVPure resin?

Yes. It uses the same affinity media as the bulk AAVPure resin, providing process homology and enabling linear scale-up from R&D to manufacturing.

Can a ready-to-use AAV chromatography column be reused?

Limited reuse is possible with proper regeneration, but single use is recommended for consistent results in small-scale applications. Contact technical support for regeneration guidelines.

How does an AAV affinity column for FPLC differ from the AAVEasy purification kit?

The AAVPure pre-packed column requires an FPLC system for precise flow and buffer control, making it suitable for process development. AAVEasy uses centrifugation for rapid purification in under 30 minutes without an FPLC system. Both use identical resin chemistry but serve different workflows.