TrueX™-ONE Universal AAV Titration Kit (ELISA)
GeneMedi's TrueX™ - ONE Universal AAV Titration Kit represents a breakthrough in AAV vector quantification, offering researchers unparalleled convenience for multi-serotype detection in a single ELISA. This innovative kit is specifically designed to simultaneously detect and quantify major AAV serotypes (AAV2, 5, 6, 8, and 9) without the need for serotype-specific reagents.
TrueX™ AAV Titration & Quantification Solution

Order information
Product Type | Catalog No. | Product Name | Size | Price(In USD) |
---|---|---|---|---|
Universal | GMV-TrueX-ELISA-U-1-96-1p | TrueX™-ONE Universal AAV Titration | 1 plate(96 wells) | |
Universal | GMV-TrueX-ELISA-U-1-96-2p | TrueX™-ONE Universal AAV Titration | 2 plate(96 wells) | |
Universal | GMV-TrueX-ELISA-U-1-96-5p | TrueX™-ONE Universal AAV Titration | 5 plate(96 wells) | |
Universal | GMV-TrueX-ELISA-U-1-96-10p | TrueX™-ONE Universal AAV Titration | 10 plate(96 wells) |
Description
Catalog number | GMV-TrueX-ELISA-U-1-96-1p/2p/5p/10p |
Product name | TrueX™-ONE Universal AAV Titration Kit (ELISA) |
Contents | 12 x 8 Determinations |
Storage | 2-8 °C |
Key components
Components | Size | Format | Storage |
---|---|---|---|
MTP (Microtiter Plate) | 12 x 8-well strips | Vacuum packing with desiccant bag | 2-8℃ |
Assay Buffer (20x) | 50 mL | Tube, dilute before use | 2-8℃ |
Biotin conjugated anti-AAV antibody (370x) | 50 μL | Tube, dilute before use | 2-8℃ |
HRP-SA (HRP labelled streptavidin, 5000x) | 5 μL | Tube, dilute before use | 2-8℃ |
TMB | 15 mL | Tube, ready to use | 2-8℃ |
Stop Solution | 15 mL | Tube, ready to use | 2-8℃ |
Validation Data
Figure 1. AAV2 capsid titration curve generated using the GenMedi AAV Titration ELISA kit
The table shows the standard concentrations of AAV 2 capsids (vp/ml) and their corresponding optical density (OD450) readings. The graph plots OD450 values against capsid concentrations, demonstrating a strong correlation (R² = 0.9998) between capsid quantity and absorbance, confirming the assay's sensitivity and accuracy.

Figure 2. AAV5 capsid titration curve generated using the GenMedi AAV Titration ELISA kit.
The table shows the standard concentrations of AAV 5 capsids (vp/ml) and their corresponding optical density (OD450) readings. The graph plots OD450 values against capsid concentrations, demonstrating a strong correlation (R² = 1.000) between capsid quantity and absorbance, confirming the assay's sensitivity and accuracy

Figure 3. AAV6 capsid titration curve generated using the GenMedi AAV Titration ELISA kit.
The table shows the standard concentrations of AAV 6 capsids (vp/ml) and their corresponding optical density (OD450) readings. The graph plots OD450 values against capsid concentrations, demonstrating a strong correlation (R² = 0.9997) between capsid quantity and absorbance, confirming the assay's sensitivity and accuracy.

Figure 4. AAV8 capsid titration curve generated using the GenMedi AAV Titration ELISA kit.
The table shows the standard concentrations of AAV 8 capsids (vp/ml) and their corresponding optical density (OD450) readings. The graph plots OD450 values against capsid concentrations, demonstrating a strong correlation (R² = 0.9997) between capsid quantity and absorbance, confirming the assay's sensitivity and accuracy.

Figure 5. AAV9 capsid titration curve generated using the GenMedi AAV Titration ELISA kit.
The table shows the standard concentrations of AAV 9 capsids (vp/ml) and their corresponding optical density (OD450) readings. The graph plots OD450 values against capsid concentrations, demonstrating a strong correlation (R² = 1.000) between capsid quantity and absorbance, confirming the assay's sensitivity and accuracy.

Click to get more Data / Case study about the product.
- GENEMEDI
- Email: [email protected] [email protected]
- Telephone: +86-21-50478399 Fax: 86-21-50478399
- Privacy Policy
- TECHNICAL SUPPORT
- Product FAQs
- Technical manuals
- Publications
- Email: [email protected]

