GeneMedi's TrueX® AAV Titration Solution is a family of serotype-specific AAV titration ELISA kits for capsid quantification, covering the five AAV serotypes most widely used in gene and cell therapy — AAV2, AAV5, AAV6, AAV8 and AAV9. Each kit is built on a double-antibody sandwich ELISA that uses a recombinant antibody directed against a conformational epitope on assembled AAV capsids, so only intact, correctly assembled viral particles are captured and quantified. Results are reported directly in capsids/mL, giving developers a dependable physical titer for process development, formulation work and lot release testing of AAV vectors.
Every kit in the TrueX® AAV Titration Solution ships complete: the serotype-matched AAV standard is already included in the box, together with a full set of ready-to-dilute reagents, so a standard curve and up to 12 × 8 determinations can be run straight out of the box — no separate standard purchase is required. Where the TrueX®-ONE Universal AAV Titration Kit (ELISA, No Standard) is designed for rapid multi-serotype screening, the serotype-specific kits are the right choice when the serotype is known and the highest specificity and most accurate absolute capsid titer are required. Learn more about the full AAV titration ELISA kits for capsid quantification portfolio.
| Product Type | Catalog No. | Product Name | Size | AAV Standard | Price (USD) | Detail |
|---|---|---|---|---|---|---|
| AAV2 | GMV-TrueX-ELISA-2-1-96 | TrueX®-AAV2 Serotype Titration Kit (ELISA) | 1 plate (96 wells) | Included | Inquiry | View Details → |
| AAV5 | GMV-TrueX-ELISA-5-1-96 | TrueX®-AAV5 Serotype Titration Kit (ELISA) | 1 plate (96 wells) | Included | Inquiry | View Details → |
| AAV6 | GMV-TrueX-ELISA-6-1-96 | TrueX®-AAV6 Serotype Titration Kit (ELISA) | 1 plate (96 wells) | Included | Inquiry | View Details → |
| AAV8 | GMV-TrueX-ELISA-8-1-96 | TrueX®-AAV8 Serotype Titration Kit (ELISA) | 1 plate (96 wells) | Included | Inquiry | View Details → |
| AAV9 | GMV-TrueX-ELISA-9-1-96 | TrueX®-AAV9 Serotype Titration Kit (ELISA) | 1 plate (96 wells) | Included | Inquiry | View Details → |
Standard curve calibration is built in. Each TrueX® serotype-specific AAV titration ELISA kit already contains the liquid AAV standard of its own serotype, matched to the antibody pair in that kit, so you can generate a full standard curve on the first run without ordering anything else.
| Kit | Catalog No. | In-Kit AAV Standard | Format | Extra Purchase Needed? |
|---|---|---|---|---|
| TrueX®-AAV2 Serotype Titration Kit (ELISA) | GMV-TrueX-ELISA-2-1-96 | AAV2 standard | Liquid | No — included |
| TrueX®-AAV5 Serotype Titration Kit (ELISA) | GMV-TrueX-ELISA-5-1-96 | AAV5 standard | Liquid | No — included |
| TrueX®-AAV6 Serotype Titration Kit (ELISA) | GMV-TrueX-ELISA-6-1-96 | AAV6 standard | Liquid | No — included |
| TrueX®-AAV8 Serotype Titration Kit (ELISA) | GMV-TrueX-ELISA-8-1-96 | AAV8 standard | Liquid | No — included |
| TrueX®-AAV9 Serotype Titration Kit (ELISA) | GMV-TrueX-ELISA-9-1-96 | AAV9 standard | Liquid | No — included |
Why the in-kit standard matters: Because the calibrator is serotype-matched to the same production lot as the kit antibodies, the standard curve, the QC acceptance criteria and the reported capsids/mL value are internally consistent — no cross-referencing between a separately purchased calibrator and the assay, and no extra cost or lead time before you can run your first plate.
The standards supplied with the kits cover routine titration. Laboratories that run lot bridging, operator proficiency testing, inter-plate variability tracking or cross-method calibration (qPCR, ddPCR, SEC-HPLC, AUC) sometimes want extra calibrator volume. For those cases, GeneMedi also offers high-purity AAV reference standards as standalone items — these are optional extras, not a requirement for running the assay.
| Product Type | Catalog No. | Product Name | Size | Price (USD) |
|---|---|---|---|---|
| Standard | GMV-TrueX-ELISA-AAV2-STD | AAV2 Standard, 1.0E+11 capsids/mL | 120 µL | $130 |
| Standard | GMV-TrueX-ELISA-AAV5-STD | AAV5 Standard, 1.0E+11 capsids/mL | 120 µL | $130 |
| Standard | GMV-TrueX-ELISA-AAV6-STD | AAV6 Standard, 1.0E+11 capsids/mL | 120 µL | $130 |
| Standard | GMV-TrueX-ELISA-AAV8-STD | AAV8 Standard, 1.0E+11 capsids/mL | 120 µL | $130 |
| Standard | GMV-TrueX-ELISA-AAV9-STD | AAV9 Standard, 1.0E+11 capsids/mL | 120 µL | $130 |
View AAV Reference Standards →
| Item | Specification |
|---|---|
| Product name | TrueX® AAV Titration Solution — Serotype-Specific AAV Titration ELISA Kits |
| Catalog numbers | GMV-TrueX-ELISA-2 / 5 / 6 / 8 / 9-1-96 (AAV2, AAV5, AAV6, AAV8, AAV9) |
| Serotypes covered | AAV2, AAV5, AAV6, AAV8, AAV9 |
| Assay format | Double-antibody sandwich ELISA, colorimetric |
| Contents | 12 × 8 determinations (1 plate / 96 wells) |
| Detection | Capture antibody-coated plate → biotin-conjugated anti-AAV antibody → HRP-labelled streptavidin → TMB, read at OD 450 nm |
| Sample types | Cell culture supernatant, purified and partially purified AAV preparations |
| Reporting unit | capsids/mL (physical titer) |
| Assay time | Approximately 3.5 hours |
| Standard | Serotype-matched AAV standard included in every kit (liquid format) — no separate purchase required |
| Storage | 2–8 °C; do not freeze. Protect TMB from light |
| Intended use | Research use only (RUO). Not for diagnostic or therapeutic procedures |
| Document | Instruction_Manual_TrueX_AAV_Titration_ELISA_Kit_0.pdf (COA available on request) |
| Component | Size | Format | Storage |
|---|---|---|---|
| MTP (Microtiter Plate) | 12 × 8-well strips | Vacuum packing with desiccant bag | 2–8 °C |
| AAV Standard (serotype-matched) | 1 vial | Tube, liquid — dilute before use | 2–8 °C |
| Assay Buffer (10×) | 50 mL | Tube, dilute before use | 2–8 °C |
| Biotin conjugated anti-AAV antibody (100×) | 150 µL | Tube, dilute before use | 2–8 °C |
| HRP-SA (HRP labelled streptavidin, 1000×) | 15 µL | Tube, dilute before use | 2–8 °C |
| TMB | 15 mL | Tube, ready to use | 2–8 °C |
| Stop Solution | 15 mL | Tube, ready to use | 2–8 °C |
The serotype-matched standard is supplied in liquid format and included in the kit; its concentration is given on the lot-specific QC sheet. Dilute all reagents per the instruction manual before use — no reconstitution required.
The TrueX® serotype-specific AAV titration ELISA is a sandwich immunoassay. AAV capsids in the sample are captured by the antibody coated on the microtiter plate, then detected by a biotin-conjugated anti-AAV antibody followed by HRP-labelled streptavidin. TMB conversion generates a colorimetric signal proportional to the amount of intact capsids present, which is read at 450 nm and interpolated against a standard curve.
Total assay time: approximately 3.5 hours.
Standard curves of AAV2, AAV5, AAV6, AAV8 and AAV9 capsids were generated with the TrueX® serotype-specific AAV titration ELISA kits. In each case the OD450 signal showed a strong correlation with capsid concentration, confirming the sensitivity and accuracy of the assay.
Figures 1–5: AAV capsid titration curves generated using the GeneMedi TrueX® AAV Titration ELISA kits. The table below summarizes the standard concentrations of AAV capsids (capsids/mL) and the corresponding optical density (OD450) readings; the graphs plot OD450 values against capsid concentration.
| Figure | Serotype | Correlation (R²) | Caption |
|---|---|---|---|
| Figure 1 | AAV2 | R² = 0.9993 | AAV2 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit |
| Figure 2 | AAV5 | R² = 0.9995 | AAV5 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit |
| Figure 3 | AAV6 | R² = 0.9999 | AAV6 capsid titration curve (shown in the composite Figure 5) |
| Figure 4 | AAV8 | R² = 0.9998 | AAV8 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit |
| Figure 5 | AAV9 | R² = 0.9998 | AAV9 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit |
Click to get more Data / Case study about the product →
The solution is a family of five serotype-specific ELISA kits — one for each of AAV2, AAV5, AAV6, AAV8 and AAV9. Every kit contains an antibody-coated microtiter plate, the serotype-matched AAV standard in liquid format, assay buffer, biotin-conjugated anti-AAV detection antibody, HRP-labelled streptavidin, TMB and stop solution. The standard is included in the kit, so no separate standard purchase is needed.
AAV2, AAV5, AAV6, AAV8 and AAV9 — the serotypes most widely used in AAV gene therapy. Each serotype is supplied as an individual kit so you only purchase the specificity your project needs.
The universal kit (GMV-TrueX-ELISA-U-1-96-NS) detects all five serotypes in a single assay format and is supplied without a standard, making it ideal for rapid screening or when the serotype is unknown. The serotype-specific kits described here use antibody-matched detection systems and include the homologous standard, and are therefore the better choice when the serotype is known and the most accurate absolute capsid titer is required.
Every TrueX® serotype-specific kit already includes the AAV standard of the matching serotype, supplied in liquid format. No separate purchase is required — the box contains everything needed to generate a standard curve and report a capsids/mL value. (Standalone reference standards are available as optional extras for laboratories that need additional calibrator volume, but they are not needed to run the assay.)
Dilute the liquid AAV standard supplied in the kit according to the lot-specific QC sheet and generate a standard curve. Determine the sample concentration by interpolating its OD450 value against the standard curve, then multiply by the sample dilution factor to obtain the original sample capsid titer in capsids/mL. Samples above the highest standard must be further diluted and re-assayed.
The kits are designed for the quantitative determination of AAV particles in cell culture supernatants and purified virus preparations. The kits are intended for research use only.
The recombinant detection antibody recognizes a conformational epitope present only on assembled capsids, so the assay quantifies intact AAV particles rather than free or dissociated capsid proteins. It does not, however, discriminate genome-containing (full) capsids from empty capsids; for the full/empty ratio, combine the capsid titer with a genome titer determined by qPCR or ddPCR.
The total assay time is approximately 3.5 hours. The sandwich ELISA workflow uses an antibody-coated plate to capture AAV particles, a biotin-conjugated anti-AAV detection antibody, HRP-conjugated streptavidin and TMB for colorimetric signal generation.
Store all components at 2–8 °C and do not freeze. Bring reagents to room temperature before use, protect TMB from light, and return unused strips to the pouch with the desiccant bag immediately after opening.
The TrueX® AAV titration ELISA kits are intended for research use only and are not licensed diagnostic or therapeutic products. For GMP implementation, bulk packaging, custom configurations or additional validation support, please contact our team at [email protected].