TrueX® AAV Titration Solution (AAV2, AAV5, AAV6, AAV8, and AAV9)

GeneMedi's TrueX® AAV Titration Solution is a family of serotype-specific AAV titration ELISA kits for capsid quantification, covering the five AAV serotypes most widely used in gene and cell therapy — AAV2, AAV5, AAV6, AAV8 and AAV9. Each kit is built on a double-antibody sandwich ELISA that uses a recombinant antibody directed against a conformational epitope on assembled AAV capsids, so only intact, correctly assembled viral particles are captured and quantified. Results are reported directly in capsids/mL, giving developers a dependable physical titer for process development, formulation work and lot release testing of AAV vectors.

Every kit in the TrueX® AAV Titration Solution ships complete: the serotype-matched AAV standard is already included in the box, together with a full set of ready-to-dilute reagents, so a standard curve and up to 12 × 8 determinations can be run straight out of the box — no separate standard purchase is required. Where the TrueX®-ONE Universal AAV Titration Kit (ELISA, No Standard) is designed for rapid multi-serotype screening, the serotype-specific kits are the right choice when the serotype is known and the highest specificity and most accurate absolute capsid titer are required. Learn more about the full AAV titration ELISA kits for capsid quantification portfolio.

Why Choose Serotype-Specific AAV Titration ELISA Kits for Capsid Quantification?

  • Serotype Precision — Each kit is engineered for one distinct serotype (AAV2, AAV5, AAV6, AAV8 or AAV9) and uses an antibody-matched detection system, delivering the most accurate intact capsid quantification for a known AAV serotype.
  • Intact-Capsid Specificity — The recombinant detection antibody recognizes a conformational epitope that only exists on assembled capsids, so the assay measures intact AAV particles rather than dissociated or free VP proteins.
  • Stable & Reliable Components — The serotype-matched AAV standard and all key reagents are supplied in a rigorously controlled liquid format — no reconstitution step — guaranteeing long-term stability, consistent lot-to-lot performance and reliable, comparable data.
  • Standard Included — No Extra Purchase — Each kit already contains the standard of its own serotype. There is nothing extra to order before you start: open the box, run the curve, read the titer.
  • High Sensitivity & Broad Dynamic Range — Optimized to detect viral particles efficiently across a robust analytical window, suitable for both highly purified preparations and complex sample matrices such as clarified cell culture supernatants.
  • Exceptional Reproducibility — Validated to minimize assay-to-assay variability, keeping critical analytical workflows stable and reproducible over time. Standard curves reach R² ≥ 0.9993 across all five serotypes.
  • Streamlined Protocol — A user-friendly, standardized ELISA workflow integrates seamlessly into existing laboratory operations, significantly reducing hands-on time and accelerating time-to-result: approximately 3.5 hours per plate.

Product List & Order Information (AAV2, AAV5, AAV6, AAV8, AAV9)

Product TypeCatalog No.Product NameSizeAAV StandardPrice (USD)Detail
AAV2GMV-TrueX-ELISA-2-1-96TrueX®-AAV2 Serotype Titration Kit (ELISA)1 plate (96 wells)IncludedInquiryView Details →
AAV5GMV-TrueX-ELISA-5-1-96TrueX®-AAV5 Serotype Titration Kit (ELISA)1 plate (96 wells)IncludedInquiryView Details →
AAV6GMV-TrueX-ELISA-6-1-96TrueX®-AAV6 Serotype Titration Kit (ELISA)1 plate (96 wells)IncludedInquiryView Details →
AAV8GMV-TrueX-ELISA-8-1-96TrueX®-AAV8 Serotype Titration Kit (ELISA)1 plate (96 wells)IncludedInquiryView Details →
AAV9GMV-TrueX-ELISA-9-1-96TrueX®-AAV9 Serotype Titration Kit (ELISA)1 plate (96 wells)IncludedInquiryView Details →

AAV Standards: Included with Every Kit — No Separate Purchase Required

Standard curve calibration is built in. Each TrueX® serotype-specific AAV titration ELISA kit already contains the liquid AAV standard of its own serotype, matched to the antibody pair in that kit, so you can generate a full standard curve on the first run without ordering anything else.

KitCatalog No.In-Kit AAV StandardFormatExtra Purchase Needed?
TrueX®-AAV2 Serotype Titration Kit (ELISA)GMV-TrueX-ELISA-2-1-96AAV2 standardLiquidNo — included
TrueX®-AAV5 Serotype Titration Kit (ELISA)GMV-TrueX-ELISA-5-1-96AAV5 standardLiquidNo — included
TrueX®-AAV6 Serotype Titration Kit (ELISA)GMV-TrueX-ELISA-6-1-96AAV6 standardLiquidNo — included
TrueX®-AAV8 Serotype Titration Kit (ELISA)GMV-TrueX-ELISA-8-1-96AAV8 standardLiquidNo — included
TrueX®-AAV9 Serotype Titration Kit (ELISA)GMV-TrueX-ELISA-9-1-96AAV9 standardLiquidNo — included

Why the in-kit standard matters: Because the calibrator is serotype-matched to the same production lot as the kit antibodies, the standard curve, the QC acceptance criteria and the reported capsids/mL value are internally consistent — no cross-referencing between a separately purchased calibrator and the assay, and no extra cost or lead time before you can run your first plate.

Optional: Additional AAV Reference Standards

The standards supplied with the kits cover routine titration. Laboratories that run lot bridging, operator proficiency testing, inter-plate variability tracking or cross-method calibration (qPCR, ddPCR, SEC-HPLC, AUC) sometimes want extra calibrator volume. For those cases, GeneMedi also offers high-purity AAV reference standards as standalone items — these are optional extras, not a requirement for running the assay.

Product TypeCatalog No.Product NameSizePrice (USD)
StandardGMV-TrueX-ELISA-AAV2-STDAAV2 Standard, 1.0E+11 capsids/mL120 µL$130
StandardGMV-TrueX-ELISA-AAV5-STDAAV5 Standard, 1.0E+11 capsids/mL120 µL$130
StandardGMV-TrueX-ELISA-AAV6-STDAAV6 Standard, 1.0E+11 capsids/mL120 µL$130
StandardGMV-TrueX-ELISA-AAV8-STDAAV8 Standard, 1.0E+11 capsids/mL120 µL$130
StandardGMV-TrueX-ELISA-AAV9-STDAAV9 Standard, 1.0E+11 capsids/mL120 µL$130

View AAV Reference Standards →

Specifications

ItemSpecification
Product nameTrueX® AAV Titration Solution — Serotype-Specific AAV Titration ELISA Kits
Catalog numbersGMV-TrueX-ELISA-2 / 5 / 6 / 8 / 9-1-96 (AAV2, AAV5, AAV6, AAV8, AAV9)
Serotypes coveredAAV2, AAV5, AAV6, AAV8, AAV9
Assay formatDouble-antibody sandwich ELISA, colorimetric
Contents12 × 8 determinations (1 plate / 96 wells)
DetectionCapture antibody-coated plate → biotin-conjugated anti-AAV antibody → HRP-labelled streptavidin → TMB, read at OD 450 nm
Sample typesCell culture supernatant, purified and partially purified AAV preparations
Reporting unitcapsids/mL (physical titer)
Assay timeApproximately 3.5 hours
StandardSerotype-matched AAV standard included in every kit (liquid format) — no separate purchase required
Storage2–8 °C; do not freeze. Protect TMB from light
Intended useResearch use only (RUO). Not for diagnostic or therapeutic procedures
DocumentInstruction_Manual_TrueX_AAV_Titration_ELISA_Kit_0.pdf (COA available on request)

Kit Components

ComponentSizeFormatStorage
MTP (Microtiter Plate)12 × 8-well stripsVacuum packing with desiccant bag2–8 °C
AAV Standard (serotype-matched)1 vialTube, liquid — dilute before use2–8 °C
Assay Buffer (10×)50 mLTube, dilute before use2–8 °C
Biotin conjugated anti-AAV antibody (100×)150 µLTube, dilute before use2–8 °C
HRP-SA (HRP labelled streptavidin, 1000×)15 µLTube, dilute before use2–8 °C
TMB15 mLTube, ready to use2–8 °C
Stop Solution15 mLTube, ready to use2–8 °C

The serotype-matched standard is supplied in liquid format and included in the kit; its concentration is given on the lot-specific QC sheet. Dilute all reagents per the instruction manual before use — no reconstitution required.

Assay Principle & Workflow

The TrueX® serotype-specific AAV titration ELISA is a sandwich immunoassay. AAV capsids in the sample are captured by the antibody coated on the microtiter plate, then detected by a biotin-conjugated anti-AAV antibody followed by HRP-labelled streptavidin. TMB conversion generates a colorimetric signal proportional to the amount of intact capsids present, which is read at 450 nm and interpolated against a standard curve.

  1. Reagent preparation. Dilute the Assay Buffer (10×) to 1× with deionized water according to the instruction manual.
  2. Standard preparation. Dilute the serotype-matched liquid AAV standard supplied in the kit according to the lot-specific QC sheet and prepare the standard dilution series — no reconstitution step, and nothing to order separately.
  3. Capture. Dilute samples in 1× Assay Buffer and add standards and samples to the coated strips; incubate to capture intact AAV capsids.
  4. Detection antibody. Wash the strips and add the biotin-conjugated anti-AAV detection antibody (diluted 1:100); incubate.
  5. Enzyme conjugate. Wash, add HRP-labelled streptavidin (diluted 1:1000) and incubate.
  6. Color development. Wash, add TMB and develop in the dark.
  7. Read. Add Stop Solution and read the absorbance at 450 nm.
  8. Calculation. Plot the standard curve, interpolate the sample OD, and multiply by the dilution factor to obtain the capsid titer in capsids/mL. Samples reading above the highest standard must be further diluted and re-assayed.

Total assay time: approximately 3.5 hours.

Applications

  • Physical titer determination (capsids/mL) of AAV vectors during upstream development, harvest and downstream purification.
  • Process development and purification optimization — tracking capsid recovery across chromatography fractions, ultrafiltration/diafiltration pools and final bulk.
  • Formulation development and stability studies, including container-closure and stress-testing comparability.
  • Full/empty capsid ratio workflows when paired with genome titer methods (qPCR / ddPCR, vg/mL).
  • In-process control and lot release QC in AAV gene therapy biomanufacturing.
  • Cross-method calibration and benchmarking against orthogonal physical titer methods such as SEC-HPLC, AUC or OD260-based estimation.
  • Serotype identity confirmation and comparability studies in preclinical research.

Validation Data

Standard curves of AAV2, AAV5, AAV6, AAV8 and AAV9 capsids were generated with the TrueX® serotype-specific AAV titration ELISA kits. In each case the OD450 signal showed a strong correlation with capsid concentration, confirming the sensitivity and accuracy of the assay.

AAV2 capsid titration curve generated using the GenMedi AAV Titration ELISA kit

Click to Zoom
Click to Zoom

AAV5 capsid titration curve generated using the GenMedi AAV Titration ELISA kit.

Click to Zoom
Click to Zoom

AAV8 capsid titration curve generated using the GenMedi AAV Titration ELISA kit.

Click to Zoom
Click to Zoom

AAV9 capsid titration curve generated using the GenMedi AAV Titration ELISA kit.

Click to Zoom
Click to Zoom

AAV2, AAV5, AAV6, AAV8, and AAV9 capsid titration curves

Click to Zoom
Click to Zoom

Figures 1–5: AAV capsid titration curves generated using the GeneMedi TrueX® AAV Titration ELISA kits. The table below summarizes the standard concentrations of AAV capsids (capsids/mL) and the corresponding optical density (OD450) readings; the graphs plot OD450 values against capsid concentration.

FigureSerotypeCorrelation (R²)Caption
Figure 1AAV2R² = 0.9993AAV2 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit
Figure 2AAV5R² = 0.9995AAV5 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit
Figure 3AAV6R² = 0.9999AAV6 capsid titration curve (shown in the composite Figure 5)
Figure 4AAV8R² = 0.9998AAV8 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit
Figure 5AAV9R² = 0.9998AAV9 capsid titration curve generated using the GeneMedi AAV Titration ELISA kit

Click to get more Data / Case study about the product →

FAQs

What does the TrueX® AAV Titration Solution include?

The solution is a family of five serotype-specific ELISA kits — one for each of AAV2, AAV5, AAV6, AAV8 and AAV9. Every kit contains an antibody-coated microtiter plate, the serotype-matched AAV standard in liquid format, assay buffer, biotin-conjugated anti-AAV detection antibody, HRP-labelled streptavidin, TMB and stop solution. The standard is included in the kit, so no separate standard purchase is needed.

Which AAV serotypes are covered?

AAV2, AAV5, AAV6, AAV8 and AAV9 — the serotypes most widely used in AAV gene therapy. Each serotype is supplied as an individual kit so you only purchase the specificity your project needs.

How is this different from the TrueX®-ONE Universal AAV Titration Kit (ELISA, No Standard)?

The universal kit (GMV-TrueX-ELISA-U-1-96-NS) detects all five serotypes in a single assay format and is supplied without a standard, making it ideal for rapid screening or when the serotype is unknown. The serotype-specific kits described here use antibody-matched detection systems and include the homologous standard, and are therefore the better choice when the serotype is known and the most accurate absolute capsid titer is required.

Does the kit include an AAV standard, or do I need to buy one separately?

Every TrueX® serotype-specific kit already includes the AAV standard of the matching serotype, supplied in liquid format. No separate purchase is required — the box contains everything needed to generate a standard curve and report a capsids/mL value. (Standalone reference standards are available as optional extras for laboratories that need additional calibrator volume, but they are not needed to run the assay.)

How is the AAV capsid concentration calculated?

Dilute the liquid AAV standard supplied in the kit according to the lot-specific QC sheet and generate a standard curve. Determine the sample concentration by interpolating its OD450 value against the standard curve, then multiply by the sample dilution factor to obtain the original sample capsid titer in capsids/mL. Samples above the highest standard must be further diluted and re-assayed.

What sample types can be tested with the TrueX® AAV titration ELISA?

The kits are designed for the quantitative determination of AAV particles in cell culture supernatants and purified virus preparations. The kits are intended for research use only.

Does the assay distinguish intact capsids from empty capsids?

The recombinant detection antibody recognizes a conformational epitope present only on assembled capsids, so the assay quantifies intact AAV particles rather than free or dissociated capsid proteins. It does not, however, discriminate genome-containing (full) capsids from empty capsids; for the full/empty ratio, combine the capsid titer with a genome titer determined by qPCR or ddPCR.

How long does the assay take?

The total assay time is approximately 3.5 hours. The sandwich ELISA workflow uses an antibody-coated plate to capture AAV particles, a biotin-conjugated anti-AAV detection antibody, HRP-conjugated streptavidin and TMB for colorimetric signal generation.

How should the kit be stored and handled?

Store all components at 2–8 °C and do not freeze. Bring reagents to room temperature before use, protect TMB from light, and return unused strips to the pouch with the desiccant bag immediately after opening.

Can the kit be used for GMP lot release or clinical testing?

The TrueX® AAV titration ELISA kits are intended for research use only and are not licensed diagnostic or therapeutic products. For GMP implementation, bulk packaging, custom configurations or additional validation support, please contact our team at [email protected].




<