SOLIDEX®-ISOEx MX1 Magnetic Separator (Cat No.:GMP-ISOEx-Mag-MX1)

This product is specifically designed for the highly efficient isolation of target cells in small-scale experiments. The SOLIDEX®-ISOEx MX1 Magnetic Separator generates a high-gradient magnetic field. When used in conjunction with the SOLIDEX®-ISOEx M Column, it ensures the optimal retention of magnetically labeled cells and high cell purity.

Product Features

  • High-Efficiency Capture: Achieves optimal purity and recovery rates even with minimal nanobead labeling.

  • Rapid and Gentle: Preserves cell viability, making it highly suitable for downstream applications such as flow cytometry analysis and immune cell preparation.

  • Broad Compatibility: Beyond its seamless integration with the SOLIDEX®-ISOEx M Column and Cell Isolation Kit & Nanobeads (Column-based), it boasts full compatibility with mainstream magnetic beads and sorting equipment available on the market.

  • User-Friendly Operation: Its standard benchtop design allows for flexible assembly with a universal stand, while the magnetic attachment mechanism ensures rapid and secure installation and removal.


SOLIDEX®-ISOEx MX1 Magnetic Separator is developed for single-channel magnetic cell isolations in combination with SOLIDEX®-ISOEx Column-Based Nanobeads and compatible columns, which can realize the rapid and gentle isolation of labeled cells by inducing a high-gradient magnetic field and ensure the stability and activity maintenance of cells.
Check GeneMedi's SOLIDEX®-ISOEx Cell Isolation Kit & Nanobeads


Order information


Catalog No. Product Name Size Price(In USD)
GMP-ISOEx-Mag-MX1 SOLIDEX®-ISOEx MX1 Magnetic Separator 1 piece 286

Description


Cat No. GMP-ISOEx-Mag-MX1
Product Name SOLIDEX®-ISOEx MX1 Magnetic Separator
Description SOLIDEX®-ISOEx MX1 Magnetic Separator is developed for single-channel magnetic cell isolations in combination with SOLIDEX®-ISOEx Column-Based Nanobeads and compatible columns, which can realize the rapid and gentle isolation of labeled cells by inducing a high-gradient magnetic field and ensure the stability and activity maintenance of cells.
Application SOLIDEX®-ISOEx MX1 Magnetic Separator is suitable for small-scale positive selection or negative selection or depletion of magnetically labeled cells using S Columns, as well as isolation of large cells (e.g., megakaryocytes) or molecules (e.g., RNA), supporting a wide range of research applications in cell biology and molecular analysis.
Format Column-based
Number of Channels 1
Storage Room temperature;Extremely Strong Magnetic Field. Keep away from computers, pacemakers, watches, and other objects that respond to magnetic fields.
Compatible Equipment SOLIDEX®-ISOEx M Column

FAQ

Q1: What is the core difference between the SOLIDEX®-ISOEx MX and LX series Magnetic Separators?
The primary difference lies in their column compatibility and corresponding cell processing capacity.
  • SOLIDEX®-ISOEx MX Series (MX1 / MX8):Specifically designed for the SOLIDEX®-ISOEx M Column, generating a high-gradient magnetic field optimized for smaller volumes. Suitable for small-scale samples up to 2×108total cells.
  • SOLIDEX®-ISOEx LX Series (LX1 / LX4):Engineered for the SOLIDEX®-ISOEx L Column, providing a uniform strong magnetic field covering a larger column volume. Ideal for large-scale samples up to 2×109total cells.
Please ensure you strictly match the separator series with the corresponding column size (M or L) to guarantee optimal isolation purity and recovery.
Q2: What factors should be considered when choosing between single-channel (MX1/LX1) and multi-channel (MX8/LX4) separators?
The selection depends primarily on your laboratory's sample throughput requirements and workflow efficiency.
  • Single-channel models (MX1 / LX1):Ideal for basic experimental setups involving individual or low-volume sample processing.
  • Multi-channel models (MX8 / LX4):Designed for high-throughput parallel processing. The MX8 accommodates up to 8 M Columns simultaneously, while the LX4 holds up to 4 L Columns. This configuration significantly reduces batch-to-batch variation and dramatically enhances efficiency for multi-sample screening.
Q3: What is the primary function of the SOLIDEX®-ISOEx Stand? Can it accommodate multiple separators simultaneously?
The SOLIDEX®-ISOEx Stand is the core base component that provides high-stability support for all the aforementioned separators. Because cell isolation requires precise buffer application and elution, the weighted design ensures absolute stability on the workbench. Furthermore, it features high modular compatibility. A single stand can securely hold one large/multi-channel unit (like an LX4 or MX8), or, via adapters, simultaneously accommodate multiple single-channel units (such as several MX1 or LX1 units), offering flexible spatial layouts for complex workflows.
Q4: Will the magnetic field strength of the separators degrade over time?
No. The entire SOLIDEX®-ISOEx Magnetic Separator lineup utilizes industrial-grade, ultra-strong permanent magnets. Under standard laboratory operating (15°C - 35°C) and storage conditions, the magnetic induction strength maintains long-term stability without degradation, requiring zero maintenance over its lifespan.
Q5: What are the guidelines for routine cleaning and maintenance of the equipment?
Please adhere to the following maintenance protocols:
  1. No Autoclaving:Extreme temperatures will cause irreversible demagnetization and structural deformation of the casing.
  2. Surface Cleaning:Regularly wipe the exterior with 70% ethanol or a 1% sodium hypochlorite solution for disinfection. Follow with a wipe-down using sterile water or a mild detergent, and allow it to air dry.
  3. Avoid Corrosion:Do not submerge the units in liquid for extended periods, and avoid using strong acidic or alkaline solvents.