Carbofuran(CAR) antibody/antigen (BSA/OVA/KLH conjugated hapten)

anti-Carbofuran(CAR) antibody and Carrier-coupled antigen/immunogen (hapten-carrier conjugates)

Target products collectionGo to Agricultural diagnostics products collection >>


Product information

Catalog No.DescriptionUS $ Price (per mg)
GMP-SMT-102-11. BSA-Carbofuran(CAR)
2. Anti-Carbofuran(CAR) mouse monoclonal antibody
$2709.00
GMP-SMT-102-21. OVA-Carbofuran(CAR)
2. Anti-Carbofuran(CAR) mouse monoclonal antibody
$2709.00
GMP-SMT-102-31. BSA-Carbofuran(CAR)
2. Anti-Carbofuran(CAR) human monoclonal antibody
$2709.00
GMP-SMT-102-41. OVA-Carbofuran(CAR)
2. Anti-Carbofuran(CAR) human monoclonal antibody
$2709.00
GMP-SMT-102-Ag-1BSA-Carbofuran(CAR)$756.00
GMP-SMT-102-Ag-2OVA-Carbofuran(CAR)$756.00
GMP-SMT-102-Ab-1Anti-Carbofuran(CAR) mouse monoclonal antibody$1953.00
GMP-SMT-102-Ab-2Anti-Carbofuran(CAR) human monoclonal antibody$1953.00

Size: 1mg | 10mg | 100mg



Product Description


BSA-Carbofuran(CAR)

Cat No.GMP-SMT-102-Ag-1
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products descriptionCompetitive immunoassay-validated hapten-carrier conjugates BSA-Carbofuran(CAR) with anti-Hapten antibody. The hapten hapten-carrier conjugates BSA-Carbofuran(CAR) had been validated with our anti-Hapten antibody Anti-Carbofuran(CAR) mouse monoclonal antibody via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


OVA-Carbofuran(CAR)

Cat No.GMP-SMT-102-Ag-2
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products descriptionCompetitive immunoassay-validated hapten-carrier conjugates OVA-Carbofuran(CAR) with anti-Hapten antibody. The hapten hapten-carrier conjugates OVA-Carbofuran(CAR) had been validated with our anti-Hapten antibody Anti-Carbofuran(CAR) mouse monoclonal antibody via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Carbofuran(CAR) mouse monoclonal antibody

Cat No.GMP-SMT-102-Ab-1
Host of AntibodyMouse IgG
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb)0.1-0.3
Products descriptionThe anti-Hapten antibody against hapten Carbofuran(CAR) had been validated with our hapten hapten-carrier conjugates BSA-Carbofuran(CAR) via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Carbofuran(CAR) human monoclonal antibody

Cat No.GMP-SMT-102-Ab-2
Host of AntibodyHuman IgG1
Bioactivity validationCompetitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb)0.1-0.3
Products descriptionThe anti-Hapten antibody against hapten Carbofuran(CAR) had been validated with our hapten hapten-carrier conjugates BSA-Carbofuran(CAR) via competitive ELISA test.
ApplicationELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
FormulationLyophilized from sterile PBS, PH 7.4
StorageStore at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Reference




    Data / case study


    Click to get more Data / Case study about the product.



    Biomarker Information


    1. Carbofuran (CAR): Carbofuran, chemically represented as 2,3-dihydro-2,2-dimethyl-7-benzofuranyl methylcarbamate, is a potent and versatile pesticide belonging to the carbamate class of chemicals. Its role in the domain of pesticides is multifaceted, primarily as an insecticide and nematicide, strategically employed for crop protection and pest management.

    Carbofuran is acclaimed for its broad-spectrum activity, effectively combating a wide array of insect pests and nematodes that pose significant threats to agricultural productivity. This chemical's mode of action involves inhibiting the enzyme acetylcholinesterase in pests, leading to paralysis and eventual mortality.

    2. Why Measure Carbofuran (CAR):

    a. Safety and Regulatory Compliance: In the context of agricultural practices, Carbofuran is subject to stringent regulatory oversight due to its potential risks to human health and the environment. Regulatory bodies set maximum residue limits (MRLs) for Carbofuran to ensure that agricultural produce, including fruits, vegetables, and grains, is safe for consumption. Accurate and precise measurement of Carbofuran levels is imperative to assess and guarantee compliance with these safety standards.

    b. Efficacy Assessment: Monitoring Carbofuran levels is of paramount importance to assess the effectiveness of pest control strategies. Farmers and pesticide manufacturers rely on quantitative data to evaluate the success of Carbofuran applications in managing pest populations and safeguarding crop yields. Regular monitoring helps optimize pesticide usage and minimize potential resistance development among target pests.

    c. Environmental Impact Mitigation: Carbofuran, like many chemical pesticides, carries the potential for environmental harm if not used judiciously. Measurement of Carbofuran concentrations in soil, water, and surrounding ecosystems is crucial for early detection of contamination. This data informs prompt action to mitigate environmental impact, safeguard non-target species, and ensure long-term ecological sustainability.

    d. Residue Detection: Detection of Carbofuran residues in agricultural commodities is pivotal for ensuring food safety and quality. Contamination with Carbofuran residues can pose significant health risks to consumers. Routine monitoring of Carbofuran levels in food products helps identify and rectify instances of contamination before they reach the market, thereby safeguarding public health.

    e. Pesticide Management and Sustainability: Beyond immediate safety concerns, measuring Carbofuran levels contributes to sustainable pesticide management practices. By accurately assessing its persistence and distribution in the environment, stakeholders can make informed decisions regarding pesticide usage, rotations, and alternative pest management strategies, ultimately promoting long-term agricultural sustainability.

    In summary, the measurement of Carbofuran levels is a pivotal aspect of modern agricultural practices, encompassing safety and regulatory compliance, efficacy assessment, environmental impact mitigation, residue detection, and sustainable pesticide management. This comprehensive understanding of Carbofuran's role underscores its significance in the biopharmaceutical industry's commitment to upholding food safety and quality standards while minimizing environmental impacts.



    About GDU


    GDU

    GDU helps global diagnostic partners in high quality of raw material discovery, development, and application. GDU believes in Protein&antibody Innovation for more reliable diagnostic solutions.