Oxytetracycline(OTCs) antibody/antigen (BSA/OVA/KLH conjugated hapten)

anti-Oxytetracycline(OTCs) antibody and Carrier-coupled antigen/immunogen (hapten-carrier conjugates)

Target products collectionGo to Antibiotics diagnostics products collection >>


Product information

Catalog No. Description US $ Price (per mg)
GMP-SMT-49-1 1. BSA-Oxytetracycline(OTCs)
2. Anti-Oxytetracycline(OTCs) mouse monoclonal antibody
$2709.00
GMP-SMT-49-2 1. OVA-Oxytetracycline(OTCs)
2. Anti-Oxytetracycline(OTCs) mouse monoclonal antibody
$2709.00
GMP-SMT-49-3 1. BSA-Oxytetracycline(OTCs)
2. Anti-Oxytetracycline(OTCs) human monoclonal antibody
$2709.00
GMP-SMT-49-4 1. OVA-Oxytetracycline(OTCs)
2. Anti-Oxytetracycline(OTCs) human monoclonal antibody
$2709.00
GMP-SMT-49-Ag-1 BSA-Oxytetracycline(OTCs) $756.00
GMP-SMT-49-Ag-2 OVA-Oxytetracycline(OTCs) $756.00
GMP-SMT-49-Ab-1 Anti-Oxytetracycline(OTCs) mouse monoclonal antibody $1953.00
GMP-SMT-49-Ab-2 Anti-Oxytetracycline(OTCs) human monoclonal antibody $1953.00

Size: 1mg | 10mg | 100mg



Product Description


BSA-Oxytetracycline(OTCs)

Cat No. GMP-SMT-49-Ag-1
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products description Competitive immunoassay-validated hapten-carrier conjugates BSA-Oxytetracycline(OTCs) with anti-Hapten antibody. The hapten hapten-carrier conjugates BSA-Oxytetracycline(OTCs) had been validated with our anti-Hapten antibody Anti-Oxytetracycline(OTCs) mouse monoclonal antibody via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


OVA-Oxytetracycline(OTCs)

Cat No. GMP-SMT-49-Ag-2
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products description Competitive immunoassay-validated hapten-carrier conjugates OVA-Oxytetracycline(OTCs) with anti-Hapten antibody. The hapten hapten-carrier conjugates OVA-Oxytetracycline(OTCs) had been validated with our anti-Hapten antibody Anti-Oxytetracycline(OTCs) mouse monoclonal antibody via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Oxytetracycline(OTCs) mouse monoclonal antibody

Cat No. GMP-SMT-49-Ab-1
Host of Antibody Mouse IgG
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb) 0.3-0.5
Products description The anti-Hapten antibody against hapten Oxytetracycline(OTCs) had been validated with our hapten hapten-carrier conjugates BSA-Oxytetracycline(OTCs) via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Oxytetracycline(OTCs) human monoclonal antibody

Cat No. GMP-SMT-49-Ab-2
Host of Antibody Human IgG1
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb) 0.3-0.5
Products description The anti-Hapten antibody against hapten Oxytetracycline(OTCs) had been validated with our hapten hapten-carrier conjugates BSA-Oxytetracycline(OTCs) via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Reference




    Validation Data


    Picture loading failed.

    Figure: GeneMedi's GMP-SMT-48-Ab-1 is validated to detect the GMP-SMT-48-Ag-1 in ELISA. IC50=0.390 ppb.


    Click to get more Data / Case study about the product.



    Biomarker Information


    1. What is Oxytetracycline (OTCs)?

    Oxytetracycline (OTCs) is a potent antibiotic belonging to the tetracycline family, making it a critical player in the realm of both human and veterinary medicine. In the scientific context, OTCs has been extensively studied for its broad-spectrum antimicrobial properties and has found applications in various fields, but its primary use remains within veterinary medicine.

    Within the tetracycline family, OTCs stands out for its bacteriostatic nature, which means it inhibits the growth and reproduction of susceptible microorganisms by interfering with their ability to synthesize proteins. This mechanism of action is particularly valuable in the management of bacterial infections, as it hinders the proliferation of pathogenic bacteria.

    2. Why Measure Oxytetracycline (OTCs)?

    The measurement of Oxytetracycline is a vital scientific pursuit, and it finds its significance in a variety of contexts:

    a. Residue Monitoring:

    One of the primary reasons for quantifying Oxytetracycline is to monitor and regulate its presence in animal-derived food products. When OTCs is administered to animals, trace amounts of the antibiotic can potentially remain in products like meat, milk, and eggs. These residues must be carefully monitored to ensure they comply with safety standards and regulations. The accurate measurement of OTCs in these food items is crucial for safeguarding public health and ensuring compliance with legal requirements.

    b. Antibiotic Stewardship:

    In the world of veterinary medicine, the prudent use of antibiotics is paramount to prevent the development of antibiotic resistance. Oxytetracycline, like other antibiotics, must be administered judiciously to maintain its effectiveness. Precise measurement of OTCs enables veterinarians to determine the appropriate dosage and treatment duration for animals. This, in turn, reduces the risk of antibiotic resistance, which is a growing concern in both human and veterinary medicine.

    c. Quality Control:

    In the pharmaceutical and veterinary product manufacturing sectors, ensuring the correct concentration of Oxytetracycline is crucial. Products that contain OTCs, such as antibiotics and vaccines, must be manufactured with precision to ensure therapeutic efficacy. Accurate measurement of OTCs content is a fundamental aspect of quality control, helping to guarantee that these products meet the necessary standards and specifications.

    d. Environmental Impact:

    Beyond the realms of animal farming, Oxytetracycline can also have environmental implications, especially in aquaculture. When used in aquatic environments, it can lead to the contamination of water bodies. Excessive presence of OTCs in aquatic ecosystems can disrupt the delicate ecological balance and harm aquatic life. Precise measurement of OTCs is, therefore, vital in aquaculture to prevent these negative environmental impacts.

    In summary, the measurement of Oxytetracycline (OTCs) is a multifaceted and critical endeavor with far-reaching implications. It ensures food safety, promotes responsible antibiotic use, upholds quality control in pharmaceuticals, and prevents environmental contamination. Our company specializes in providing the scientific tools and expertise needed for accurate OTCs quantification, catering to the diverse requirements of these important applications. We offer a range of solutions, including anti-OTCs antibodies and competitive antigens, to meet the demands of scientific rigor, environmental sustainability, and public health.



    About GDU


    GDU

    GDU helps global diagnostic partners in high quality of raw material discovery, development, and application. GDU believes in Protein&antibody Innovation for more reliable diagnostic solutions.